Key Takeaways
- Malaysian building law treats a warehouse and a factory as different buildings. The Uniform Building By-Laws 1984 put a factory in purpose group VI and a warehouse in group VIII (storage and general), and exits, fire resistance and compartment sizes follow the group.
- On the land title there is usually no difference: under section 117 of the National Land Code, land in the "industry" category may carry factories and warehouses alike, unless an express condition on the title narrows the use.
- Power is a capacity question, not a tariff one. Since 1 July 2025 TNB groups non-domestic customers by supply voltage, so a factory and a warehouse on the same voltage are on the same tariff. What differs is how many amps the process needs.
- Running production in a warehouse is a change of use. It needs planning permission under the Town and Country Planning Act 1976, a council licence for the new activity, and possibly a MIDA manufacturing licence, a DOE notification and a fresh look at the Bomba fire certificate.
- Going the other way is not automatic either. A single storey warehouse above 3,000 m² needs 4 hour fire resistance where a factory needs 2, and Bomba lists sprinklered storage buildings as designated premises from 1,000 m² against 2,000 m² for a factory.
Many listings call any steel-framed industrial building a factory, and many owners use the words loosely. The law does not. This guide sets out where a warehouse and a factory really differ in Malaysia (building specs, power, floor loading, approvals and licences) and what it takes to use one as the other. It is general information, not legal advice.
What is the difference between a warehouse and a factory?
The difference is the activity inside, and each set of rules defines it in its own words.
- Building law. The Fifth Schedule of the Uniform Building By-Laws 1984 (UBBL), gazetted on 12 September 1985, defines purpose group VI, Kilang (factory), as premises within the meaning of section 2 of the Factories and Machinery Act 1967, excluding buildings classified in group VIII. Group VIII, Storan dan am (storage and general), covers places for storing, depositing or placing goods and materials, including vehicles. By-law 134 says every building or compartment is classed by its use or intended use, and where a building serves more than one purpose, only its main use decides the group. A factory with a stock room is still a factory.
- Licensing. The Industrial Coordination Act 1975, as quoted by MIDA, defines manufacturing activity as "the making, altering, blending, ornamenting, finishing or otherwise treating or adapting any article or substance with a view to its use, sale, transport, delivery or disposal", including the assembly of parts, but not activities normally associated with retail or wholesale trade.
- Customs. A licensed warehouse is licensed under section 65 of the Customs Act 1967, while a licensed manufacturing warehouse (LMW) is a licensed warehouse that also holds an additional licence to carry on a manufacturing process under section 65A.
In short: if goods are made, altered, assembled or treated, the building is being used as a factory. If goods are received, held and dispatched, it is a warehouse.
| Item | Warehouse | Factory |
|---|---|---|
| UBBL purpose group | VIII, storage and general | VI, factory |
| Design occupant load (UBBL Seventh Schedule) | 30 m² gross per person | 10 m² gross per person |
| Fire resistance, single storey above 3,000 m² | 4 hours | 2 hours |
| Bomba designated premises (sprinklered) | 1,000 m² or 7,000 m³ and above | 2,000 m² and above, or hazardous processes |
| MIDA manufacturing licence | Not for storage alone | Shareholders' funds of RM2.5 million and above, or 75 or more full-time employees |
| Customs bonded status | Licensed warehouse, section 65 | LMW, section 65A |
| Land title category | "Industry" | "Industry" |
| TNB tariff | Non-domestic, by supply voltage | Same |
How do the building specs of a warehouse and a factory differ?
How many people the building is designed for
The UBBL Seventh Schedule, as replaced by the Uniform Building (Amendment) By-Laws 2021, sets the occupant load at 10 m² gross per person for a factory and 30 m² gross per person for a warehouse. Exit widths and staircases are sized from that figure. Worked through, a 3,000 m² floor is designed for about 100 people as a warehouse and about 300 as a factory. That is the main reason a warehouse filled with production workers often needs more or wider exits.
Travel distance to an exit is the same for a general factory and a low or ordinary hazard store: 30 m unsprinklered and 60 m sprinklered for two-way travel. High hazard use is tighter: 22 m and 35 m for a factory, 20 m and 35 m for storage.
Fire resistance and compartment size
For single storey buildings, the amended Ninth Schedule sets the fire resistance of the structure by floor area:
| Floor area (single storey) | Factory | Warehouse (storage and general) |
|---|---|---|
| Up to 500 m² | ½ hour | ½ hour |
| Up to 1,000 m² | ½ hour | 1 hour |
| Up to 2,000 m² | ½ hour | 2 hours |
| Up to 3,000 m² | 1 hour | 2 hours |
| Above 3,000 m² | 2 hours | 4 hours |
For buildings of more than one storey up to 28 m high, the Fifth Schedule caps a compartment at 28,000 m³ for a factory and 21,000 m³ for storage, and the proviso to by-law 136 doubles those limits where the building has sprinklers to MS 1910. Where one building holds both uses, by-law 138 requires the wall or floor between parts used mainly for different purpose groups to be built as a compartment wall or floor.
Loading, height and layout
A warehouse earns its keep on throughput: loading bays and dock levellers, truck turning space, clear height under the sprinklers for racking, and a floor flat and strong enough for racking and reach trucks. A factory is planned around its process: power, ventilation, drainage for wash-down, space between machines, staff facilities and sometimes crane beams. You can filter units on power, clear height, floor loading and loading bays with the spec search.
How does the power supply differ?
The tariff is the same since July 2025
TNB's tariff restructuring groups customers by supply voltage. The old Tariff B (low voltage commercial) and Tariff D (low voltage industrial) both became the Non-Domestic Low Voltage General or ToU Tariff, and Tariffs C1 and E1 both became the Non-Domestic Medium Voltage General Tariff. A warehouse is therefore not billed at a cheaper "commercial" rate than a factory on the same voltage. Our TNB ToU guide shows when the time-of-use option saves money.
The difference is capacity
TNB's supply voltage options depend on maximum demand:
| Maximum demand | Supply TNB provides |
|---|---|
| Up to 72 kVA (100A) | 400V three-phase, four-wire |
| Up to 1,000 kVA | 400/230V, CT metered |
| 1,000 to 5,000 kVA | 11kV |
| 5,000 to 25,000 kVA | 33kV |
| Above 25,000 kVA | 132kV or 275kV |
Under TNB's connection guidelines, a single development up to 350 kVA may need a new 11/0.4kV substation subject to a TNB study, and above 350 kVA but below 1,000 kVA a new substation is required. A store that only runs lights, dock doors and forklift chargers can sit at the bottom of this table, while a production line in the same shell can push it into a substation. Before converting, list the machines in the factory power calculator and compare the total with the supply the building already has.
How much floor loading does each need?
Racking and machines load a floor in different ways. Pallet racking brings heavy loads down through small base plates in long rows, while machines bring point loads, vibration and sometimes pits or plinths. The figure that matters is the design load on the approved structural drawings, not a number in an advert. Estimate your own load with the floor loading calculator, then ask a structural engineer to compare it with the drawings.
Which approvals and licences change?
| Approval | What changes between warehouse and factory | Rule |
|---|---|---|
| Land title | Usually nothing: "industry" land may be used for factories and warehouses for manufacture, storage or distribution. Express conditions on the title prevail over these implied conditions, and buildings may not be altered or extended without prior written consent | National Land Code s.117 |
| Planning permission | A material change in the use of a building, or part of it, is development and needs planning permission. Interior works are exempt only if they involve no change in use | TCPA 1976 s.2 and s.19 |
| Council licence | One industrial licence stream covers factories and warehouses, but no activity beyond the licensed one is allowed, and making or processing may only happen at premises with industrial or factory status | MBDK licence conditions |
| MIDA manufacturing licence | Needed for manufacturing with shareholders' funds of RM2.5 million and above, or 75 or more full-time employees; smaller companies may apply for exemption | Industrial Coordination Act 1975 |
| DOE | Premises that discharge industrial effluent fall under the regulations, and work that may create a new discharge needs prior written notice to the Director General | Industrial Effluent Regulations 2009, reg. 3 and 4 |
| Bomba fire certificate | Different thresholds for factory and storage | Designated premises schedule, P.U.(A) 289/2020 |
| Customs | Licensed warehouse (s.65) versus LMW (s.65A) | Customs Act 1967 |
The Industrial Effluent Regulations define industrial effluent as liquid waste or wastewater generated from a manufacturing process or any activity at industrial premises. For the council side in Klang, this klangindustrial.com guide to the licence Klang's council issues for factories and warehouses lists what the council checks.
Can a warehouse be used as a factory?
Yes, if the land, the building and the licences allow the new use, but not by moving machines in. A practical order:
- Read the title. Confirm the "industry" category and read every express condition. If a condition names a narrower use, the owner applies to the State Authority to amend it under section 124 of the National Land Code.
- Get the approved plans and the CCC. See what use the building was approved for. Our CCC guide explains how to check it.
- Ask the council's planning department whether your process is a material change of use. Under section 2(3)(d) of the Act, any use contrary to the development plan always is. If permission is needed, apply before you start.
- Recheck the building for group VI. A qualified person checks exits for three times the occupant load, fire resistance, compartments and any new partitions, and submits changes to the council and Bomba. MBDK's conditions require council approval before any building work on industrial premises.
- Check the power against your machine list and apply to TNB if it falls short.
- Apply for the council licence for the manufacturing activity. A licence held for storage does not cover production, and MBDK licences cannot be transferred without the council's written permission.
- Federal and environmental items: a MIDA manufacturing licence or exemption, and written notice to DOE before works that may create a new effluent discharge.
- Tenants: get the landlord's written consent to the use and the works before you sign, and make the approvals a condition of the lease.
Can a factory be used as a warehouse?
Often with less work, but check three things. First, fire: a large single storey store needs higher fire resistance than a factory of the same size, and Bomba lists sprinklered storage from 1,000 m² or 7,000 m³. High racking added to an old factory can change what the fire systems must do. Second, the council licence must name storage if storage becomes the business. Third, ask the planning department whether the switch is a material change of use for that site.
What do buyers and tenants get wrong?
- Treating an industrial title as permission for any use. The title is one layer; planning, building and licensing are separate.
- Relying on the previous occupier's licence or fire certificate. Licences are issued for an activity and a licensee.
- Assuming a factory pays a higher electricity rate. Since July 2025 the tariff follows voltage; the cost difference is the upgrade.
- Forgetting the people count. A warehouse designed for 30 m² per person may not have the exits for a production team.
- Signing first and applying later. Put the approvals into the lease or SPA conditions.
Frequently Asked Questions
What is the difference between a warehouse and a factory?
A warehouse stores and moves goods; a factory makes, alters, assembles or treats them. Malaysian building law puts them in different purpose groups (VIII and VI under the UBBL), which changes exits, fire resistance and compartment limits, while licensing law adds a MIDA manufacturing licence only for manufacturing above set thresholds.
What is a warehouse under Malaysian building law?
The UBBL Fifth Schedule defines purpose group VIII, storage and general, as a place for storing, depositing or placing goods and materials, including vehicles, and other premises not in groups I to VII. Its design occupant load is 30 m² gross per person.
Can a warehouse be used as a factory in Malaysia?
Yes, once the change is approved. Turning storage into production is a material change of use, so check the title's express conditions, get planning permission where the council requires it, recheck exits and fire resistance for a factory, and get a council licence for the manufacturing activity. A MIDA licence or exemption and a DOE notice may also apply.
Can I use a factory as a warehouse?
Usually, but not without checks. Storage has stricter fire resistance than a factory in large single storey buildings, Bomba's fire certificate threshold for sprinklered storage starts at 1,000 m², and the council licence must cover storage as the business activity.
Do factories pay a higher TNB electricity tariff than warehouses?
No. Since 1 July 2025 TNB groups non-domestic customers by supply voltage, so the old commercial and industrial tariffs were merged into one non-domestic tariff per voltage level. A factory usually pays more in total because it uses more power and may need a bigger supply or a substation.
Does a warehouse need a MIDA manufacturing licence?
Not for storage alone. The Industrial Coordination Act 1975 requires a manufacturing licence for manufacturing activity by companies with shareholders' funds of RM2.5 million and above or 75 or more full-time employees, and its definition excludes activities normally associated with retail or wholesale trade.
Does a warehouse need a Bomba fire certificate?
A sprinklered storage building of 1,000 m² or more, or 7,000 m³ or more, is a designated premises and needs a fire certificate renewed every year. For a factory the sprinklered threshold is 2,000 m², and special structures with hazardous processes are listed separately.
What is the difference between a licensed warehouse and an LMW?
Both are Customs licences. A licensed warehouse is a warehouse or place licensed under section 65 of the Customs Act 1967, while a licensed manufacturing warehouse (LMW) is a licensed warehouse that also holds an additional licence under section 65A to carry on a manufacturing process. Storage needs only the first; production under bond needs the second.
FactoryHub is dedicated to helping every client find the right factory or warehouse. If you are deciding between a warehouse and a factory, or want a unit whose approvals already match your activity, call Peter Tan (REN 12771) at 016-666 6872 or Jason Low (PEA 1478) at 012-288 1834.