Key Takeaways
- Choose a single storey factory when the work is heavy: machines, forklifts, high racking, container loading or an overhead crane. Choose a double storey or 1.5 storey factory when the upper floor will hold offices, QC, light assembly or light stock and you want more floor on the same land.
- The upper floor is a suspended slab with its own design load. Selangor's building by-laws require floor loads to follow MS EN 1991-1-1, special floor design where forklifts run, and each floor's design load marked on the structural plans, so ask for those plans before anything heavy goes upstairs.
- No lift is required by law in a factory of four storeys or fewer, but any goods lift or hoist you install falls under DOSH's 2024 regulations: a certificate of fitness valid for 15 months, servicing every month and a comprehensive examination at least every three months.
- Fire rules tighten with a second floor: under the Tenth Schedule a single storey factory needs sprinklers above 2,000 m² of floor, a two storey factory above 1,000 m² per floor.
- JPPH-registered sale prices are per sq ft of land and do not separate storeys or building age. Compare built-up area floor by floor, and judge an older factory on its land, its papers and what its structure can still carry.
Single storey or double storey factory: which should you choose?
Choose on the job the building must do, not on the total floor area. Heavy goods, forklifts, high racks and overhead cranes belong on a ground-bearing slab in one hall, which points to a single storey building. Offices, design rooms, QC labs, light assembly, sample rooms and light stock can sit upstairs, so a double storey or 1.5 storey building gives you that space without giving up production floor.
What 1.5, 2 and 2.5 storey mean for a factory
- Single storey: one production hall, sometimes with a small office inside it.
- 1.5 storey: a single storey production hall with a two storey office block, usually at the front. The "half" is the upper office floor, not a second production floor.
- 2 storey (double storey): a full upper floor over all or most of the footprint, used for production, storage or offices.
- 2.5 or 3.5 storey: a production hall with an office block of two or three floors, common in semi-D and terrace units.
The description in an advert is not a plan. Ask for the approved building plan to see which floors exist, their area and their approved use.
Side by side
| What you need | Single storey | Double storey |
|---|---|---|
| Heavy machines, forklifts, racking | Anywhere on the ground slab | Ground floor, unless the upper slab was designed for it |
| Overhead crane | Possible where the structure was built for one | Usually only in a full height hall |
| Moving goods | One level, shortest path | Lift, hoist, conveyor or ramp between floors |
| Floor area on the same land | Limited by the ground footprint | More floor on the same footprint |
| Fire systems | Thresholds on total floor area | Lower thresholds per floor |
| Offices and staff | Office takes production floor | Office upstairs frees the ground floor |
How much load can the upper floor of a double storey factory take?
Only what its engineer designed it for. The ground floor rating tells you nothing about the floor above, so ask for the design load of each floor in kN/m².
Selangor's Uniform Building By-Laws 1986 say that all imposed floor loads shall be calculated in accordance with MS EN 1991-1-1 (by-law 59), that where forklift trucks may be used special provision shall be made in the floor design (by-law 60), and that structural plans shall be clearly marked with the imposed loads each floor was designed for (by-law 16(3)). The current loading standard came in with the amendment Sel. P.U. 142/2012, in force from 27 December 2012, so a factory approved before then was designed under the older rules.
What to check on site
- Ask for the approved structural plans, or an engineer's letter, giving the imposed load of the upper floor and any forklift it was designed for.
- Look for a lift pit or hoist shaft. If there is none, the upper floor was most likely planned for offices.
- List what you will put upstairs: rack bay weights, machine weights and base sizes, pallet trucks. The floor loading calculator turns them into kN/m² for comparison with the plan.
- If the figures are close or missing, have a Professional Engineer check before you sign, not after the machines arrive.
Our factory floor loading guide explains kN/m², point loads, forklift classes and mezzanines in detail, so this guide does not repeat them.
How do goods get upstairs: goods lift, hoist, conveyor or ramp?
Usually by a goods lift or a material hoist, sometimes by a vertical conveyor, and in a few purpose-built buildings by a ramp that lorries drive up. The by-laws do not force a lift on a two storey factory, but once one is installed, DOSH's rules apply in full.
What the building by-laws require
By-law 124 requires at least one lift only in non-residential buildings exceeding 4 storeys above or below the main access level. By-law 197A requires fire lifts where the top occupied floor is over 18.5 metres above fire appliance access level. A normal two storey factory meets neither test, so a lift is a business decision.
What DOSH requires once you install one
Under the Occupational Safety and Health (Plant Requiring Certificate of Fitness) Regulations 2024, in force since 1 June 2024, lifting machinery is plant that needs a certificate of fitness. The regulations define a lift as one carrying persons only, or persons and goods, and a material hoist as hoist equipment attached to the building and used to raise and lower material.
| Requirement for a lift | Rule in the 2024 regulations |
|---|---|
| Certificate of fitness | Valid for 15 months from the inspection date |
| Servicing and adjustment | Not less than once a month, by a competent person |
| Comprehensive examination | At least once every three months, or more often if the manufacturer's manual says so |
| Maintenance agreement | With a competent person, for not less than one year |
| DOSH inspection fee, lift travelling less than 12 metres | RM650 |
| DOSH inspection fee, material hoist | RM350 to RM1,000, by safe working load |
Skipping the comprehensive examination is an offence carrying a fine of up to RM100,000, up to one year in jail, or both. Forklifts and other material handling equipment, dock levellers, vertical conveyors and lorry tail lifts are listed in the Third Schedule as outside these regulations.
These are DOSH's fees only. The lift itself, its pit, shaft and floor openings are building work priced by the installer and contractor. There is no official figure, so get at least two quotes. Ms Teh's partner guide to goods lifts and overhead cranes in a Klang factory walks through the DOSH approval for a new installation.
What to check on site
- The current DOSH certificate of fitness, the rated load in kilograms and the car size against your pallets and trolleys.
- The maintenance agreement, and the recent comprehensive examination reports, which the regulations require to be kept on the premises.
- Where the lift opens: next to the loading bay, or at the far end of the hall.
- For a ramp, the gradient, width and turning space on the approved plan, measured against your own lorries.
Do fire rules differ for single and double storey factories?
Yes. A second floor brings sprinklers in at a smaller size, needs exits on every storey, and in large buildings brings compartment limits that a single storey building does not face.
The Tenth Schedule of the Selangor by-laws sets fixed fire systems by floor area:
| Factory in the Tenth Schedule | 25 kg trolley extinguisher | Hose reels | Hose reels and sprinklers |
|---|---|---|---|
| Single storey detached or terrace unit | 750 to 1,000 m² | 1,001 to 2,000 m² | More than 2,000 m² (about 21,530 sq ft) |
| Two storey detached or terrace unit, each floor a separate compartment | Under 500 m² per floor | 500 to 1,000 m² per floor | More than 1,000 m² per floor (about 10,760 sq ft) |
A single storey unit under 750 m² needs no fixed system. Fire detection and alarm requirements step up through the same bands, and factories with special risks or hazardous processes must provide whatever the Director General of Fire and Rescue requires on top.
A worked illustration with a hypothetical building: on a footprint of 1,500 m² (about 16,150 sq ft), a single storey factory sits in the hose reel band, while the same footprint built as two full floors of 1,500 m² each sits in the sprinkler band. Sprinklers add a water tank, pumps and piping, so cost them in before adding or converting an upper floor.
Two more by-laws matter upstairs:
- Exits: by-law 166 requires at least two separate exits from each storey, within the travel distances of the Seventh Schedule. For a general factory, that is 30 metres without sprinklers and 60 metres with them.
- Compartments: by-law 136 applies to every building other than a single storey building. A factory not exceeding 28 metres in height may have no compartment larger than 28,000 m³ (21,000 m³ for storage), and the limits are doubled where an MS 1910 sprinkler system is installed.
How do production flow and office space change?
A single storey hall lets material move in one line from receiving to dispatch. A double storey building splits that flow, so keep everything that moves often on the ground floor and send people, not pallets, upstairs.
Production flow
- Single storey: receiving, process, packing and dispatch can run in a straight line or a U, with forklifts and pallet trucks, and the layout is easy to rearrange.
- Double storey: every pallet that goes up has to come down. The lift sets the pace, and when it stops for servicing or a fault, upstairs work stops. Plan the upper floor for light, low frequency loads: small parts assembly, sewing, light packing, sample rooms, records and staff areas.
- Headroom: by-law 44(6) requires at least 3 metres of headroom in any factory room where people work. Measure the upper floor's floor to ceiling height, not only the hall's clear height.
Office share and car parks
Selangor's planning manual treats up to 30% of the gross floor area of detached and semi-D factories as office, and caps the building footprint (plinth area) at 60% of the site. That is why an upper floor is the usual way to add office and floor space on a fixed lot. Every square foot added also counts for parking: the manual asks for 1 car bay per 500 sq ft of office, 1 per 1,000 sq ft of production floor and 1 per 2,500 sq ft of store, plus 10% for visitors. Adding a floor is building work that needs council approval. How office and production floor are counted in price and rent is covered in our built-up area vs land area guide.
What do single and double storey factories cost per sq ft?
The registered records do not separate single and double storey factories, so there is no official price or rent gap between them to quote. They do give the price per sq ft of land and the rent per sq ft of floor by factory type.
JPPH-registered transactions in Selangor and Kuala Lumpur, 24 months to August 2026 (Selangor & Kuala Lumpur transaction prices and rents):
| Factory type | Median price | Price per sq ft of land | Median land | Registered rent |
|---|---|---|---|---|
| Terrace factory | RM1.17 million | RM518 psf of land | 2,002 sq ft | RM1.62 psf/month |
| Semi-detached factory | RM4.9 million | RM375 psf of land | 12,350 sq ft | RM1.75 psf/month |
| Detached factory | RM10 million | RM281 psf of land | 38,865 sq ft | RM1.38 psf/month |
How to use these figures for a storey decision:
- Sale prices are per sq ft of land. Two semi-Ds on the same lot, one 1.5 storey and one full double storey, can register a similar land psf even though one has much more floor. Once you have the approved plans, divide the price by the built-up area of each floor and decide what the upper floor is worth to your operation.
- Rents are per sq ft of rented floor area. When the upper floor is counted in the rented area, the rate per sq ft looks lower, but you pay for that floor whether you can use it or not. Work out the rent per sq ft of usable ground floor as a second figure.
- Compare within the same type and estate. Prices move with the park, tenure, condition and power supply, so a state median is a starting point only.
Old factory or modern factory: which holds value better?
Land carries most of a factory's value and does not age, so an older factory in a sound estate can hold its value well. What an older building loses is fitness for today's users. Price an older factory on its land and its papers, then subtract the cost of bringing it up to what you need.
Rule changes that date a factory
| In force from | Change | What it means for an older factory |
|---|---|---|
| 12 April 2007 | The CCC replaced the certificate of fitness for occupation, with one enforcement date for all states | Older factories usually hold a certificate of fitness for occupation (CF) instead of a CCC; check that one or the other exists |
| 27 December 2012 | Sel. P.U. 142/2012: floor loads to MS EN 1991-1-1 and a new Tenth Schedule of fire systems | Floors and fire systems were designed to the older rules |
| 1 June 2024 | DOSH's 2024 regulations on plant requiring a certificate of fitness | An existing goods lift needs a current certificate and maintenance under today's rules |
What the tax rules say about an older building
LHDN Public Ruling No. 3/2018 says that since year of assessment 2005, the qualifying expenditure on a purchased industrial building is the purchase price of the building, including legal fees and stamp duty but excluding the land. Its own example: a furniture factory built in 1962 and sold in 2017 for RM250,000, building only, gives the buyer qualifying expenditure of RM250,000. The initial allowance is generally 10% and the annual allowance 3%. Where the price does not split land and building, the ruling asks for a valuation by JPPH or a professional valuer, so for an owner-occupier buying an older factory, the valuer's split decides how much allowance can be claimed. This guide explains building, safety and tax rules in general terms and is not legal or tax advice.
Older factory checklist
- CCC or CF, and council approval for every extension built after it (what a CCC is and why it matters).
- Design floor loads on the structural plans, and whether your loads fit them.
- Fire systems against today's Tenth Schedule for your floor area and number of storeys.
- Roof, gutters, drains and the TNB supply against your machine list.
- For a leasehold title, the years left on the lease, which buyers and banks look at more closely than the building's age.
Which businesses suit a single or double storey factory?
| Business | Usually suits | What decides it |
|---|---|---|
| Metal fabrication, machining, heavy engineering | Single storey | Machine weight, cranes, forklifts, clear height |
| Warehousing and logistics with pallet racking | Single storey | High racks, forklifts, container loading at ground level |
| Plastic moulding, printing, packaging lines | Single storey hall, office upstairs | Machine weight and material flow stay on the ground slab |
| Electronics and small parts assembly, garments, light packing | Double storey or 1.5 storey | Light loads, many staff, offices and QC upstairs |
| Trading firms with offices, samples and light stock | 1.5 storey or double storey | Offices and samples upstairs, stock and dispatch below |
| Small parcel e-commerce | Either | Single storey once volume needs racking and forklifts; upstairs only for light picking with a reliable lift |
Common mistakes:
- Using the ground floor load rating for the upper floor.
- Reading a 1.5 storey advert as two production floors.
- Taking over a goods lift with no current certificate of fitness or maintenance agreement.
- Turning upstairs offices into production without checking loads, exits and the sprinkler threshold.
- Comparing land psf between units with very different floor areas.
Practical steps: more questions
How often must a factory goods lift be inspected?
Its DOSH certificate of fitness is valid for 15 months from the inspection date, and the periodical inspection falls no earlier than the first day of the twelfth month after the last one. Between inspections, a competent person must service it at least monthly and carry out a comprehensive examination at least every three months.
Frequently Asked Questions
Where can I find a factory for rent with a goods lift?
Look at double storey factories and units with upper production or storage floors, since goods lifts serve upper floors and the law does not require a lift in a factory of four storeys or fewer, so only some units have one. When you find one, ask for its current DOSH certificate of fitness, the rated load in kilograms, the car size against your pallets and trolleys, and the maintenance agreement, and check the upper floor's design load. Peter Tan or Jason Low can shortlist units whose lift and papers suit your goods.
What does 1.5 storey factory mean?
A 1.5 storey factory is a single storey production hall with a two storey office block, usually at the front. The "half" storey is the office floor above part of the building, not a second production floor. Check the approved plan to see how large the upper floor is and what load it was designed for.
Is a single storey factory better than a double storey factory?
It is better for heavy, forklift-driven or racked operations, because everything sits on the ground slab and moves on one level. A double storey factory is better when much of your space is offices, QC, light assembly or light stock and you want more floor on the same land. Decide from your heaviest load and how often goods move between floors.
Does a double storey factory need a goods lift by law?
No. Selangor's by-law 124 requires a lift only in non-residential buildings exceeding four storeys. If you install a goods lift or material hoist anyway, it needs a DOSH certificate of fitness, monthly servicing and a comprehensive examination at least every three months.
Can I put a forklift or heavy machines on the upper floor?
Only if the upper floor was designed for them. By-law 60 requires special provision in the floor design where forklifts may be used, and by-law 16(3) requires the design load of each floor to be marked on the structural plans. Ask for those plans and have a Professional Engineer confirm your loads before moving anything up.
Do I need sprinklers in a two storey factory?
Under the Tenth Schedule of the Selangor by-laws, a two storey factory with each floor as a separate compartment needs hose reels and sprinklers once a floor exceeds 1,000 m², about 10,760 sq ft. A single storey factory reaches the sprinkler band only above 2,000 m². Bomba can require more for special risks or hazardous processes.
Is a double storey factory cheaper per sq ft?
There is no registered figure that separates single and double storey factories, because JPPH sale prices are recorded per sq ft of land. A double storey unit often gives more floor for the land price, but upper floor area is worth less to a heavy user. Divide the price or rent by the built-up area of each floor and value the upper floor by what you can actually do on it.
Is an old factory worth less than a new one?
Not necessarily, because land carries most of the value and does not age. An older factory loses value when its papers, floor loads, fire systems, power or roof fall short of what today's users need, or when a leasehold title has few years left. Price it on registered land prices in the same estate, then subtract the cost of the upgrades you need.